VIP vehicle priority traffic control.
Manual phase stepping control.
Pedestrian crossing trigger control.
Centralized coordinate control by the command center.
Multi – periods of fixed time control.
Self–adaptive arterial and area coordinate control.
Off-line arterial and area coordinate control.
Wireless adjustment control via an optional GPS module. Optional.
Single point self-adaptive control.
Actuated/semi-actuated control.
Traffic data acquisition and analysis. Optional.
Yellow flashing and all red modes.
Betex Traffic Solution (Intersection controller) Series is Intersection Traffic Light Control Solution that have been Developed by PEX Trafik team by applying our long experience in this field which exceeded 30 years of direct interacted with different municipalities.
The full automated Intersection control systems which been fully designed by PEX Trafik Automation Engineer Team are complying with international Traffic regulation and related Standard TS EN 50556, moreover considering the varicosity in demands BETI Control Series operated system are self-enhanced to apply different operation factors that would be requested to be implemented either from Municipality or related traffic management department such as Police department.
BETI intersection control unit can be provided with 4 different sizes as standard production lines. The assigned capacities were adjusted to meet the continues requests which we are receiving, however PEX Trafik are capable to provide special solution to meet the costumer special case.
BETEXController was developed to keep up with the real time situation of the market, so the control system can be integrated with existing SCADA system (SMART CITY) as the controller can be equipped with extra optional modules that would provide the possibility data acquisition requested by exsisting SCADA Systems.
TECHNICAL SPEICIFICATION | |
Control Unit Code | BETEX 32 + UPS |
Electrical Condition |
Operating Voltage: 220-230 VAC Operating Output Voltage:220 VAC or 42 VAC Operating Frequency : 50 Hz Power Factor : >0.9 |
Enviromental Condition |
Temperature : -25˚C, +60˚C Humidity : 95% IP : IP65 |
Standard | EN 50556 , TS HD 638 S1, TS EN 12675 ,EN 50293 |
System Standard Features |
Lighting Group : 32 Lighting Group
Pedestrian Cross Button : 12 Button Loop Detector : 12 Sensore Local Text HMI |
Communication |
Ethernet TCP/IP Serial RS 232 |
Optional Feature |
Back Up Power : UPS or Solar System CPU : Dual CPU Communication : RS 485 , GSM , GPS SCADA : RUNTIME and Alarm Logger Local Display : Colur Touch HMI Screen |
TECHNICAL SPEICIFICATION | |
Control Unit Code | BETEX 24 |
Electrical Condition |
Operating Voltage: 220-230 VAC Operating Output Voltage:220 VAC or 42 VAC Operating Frequency : 50 Hz Power Factor : >0.9 |
Enviromental Condition |
Temperature : -25˚C, +60˚C Humidity : 95% IP : IP65 |
Standard | EN 50556 , TS HD 638 S1, TS EN 12675 ,EN 50293 |
System Standard Features |
Lighting Group : 24 Lighting Group
Pedestrian Cross Button : 8 Button Loop Detector : 8 Sensore Local Text HMI |
Communication |
Ethernet TCP/IP Serial RS 232 |
Optional Feature |
Communication : RS 485 , GSM , GPS SCADA : RUNTIME and Alarm Logger Local Display : Colur Touch HMI Screen |
TECHNICAL SPEICIFICATION | |
Control Unit Code | BETEX 16 |
Electrical Condition |
Operating Voltage: 220-230 VAC Operating Output Voltage:220 VAC or 42 VAC Operating Frequency : 50 Hz Power Factor : >0.9 |
Enviromental Condition |
Temperature : -25˚C, +60˚C Humidity : 95% IP : IP65 |
Standard | EN 50556 , TS HD 638 S1, TS EN 12675 ,EN 50293 |
System Standard Features |
Lighting Group : 16 Lighting Group
Pedestrian Cross Button : 4 Button Loop Detector : 4 Sensore Local Text HMI |
Communication |
Ethernet TCP/IP Serial RS 232 |
Optional Feature |
Communication : RS 485 , GSM , GPS SCADA : RUNTIME and Alarm Logger |
TECHNICAL SPEICIFICATION | |
Control Unit Code | BETEX Pedestrian |
Electrical Condition |
Operating Voltage: 220-230 VAC Operating Output Voltage:220 VAC or 42 VAC Operating Frequency : 50 Hz Power Factor : >0.9 |
Enviromental Condition |
Temperature : -25˚C, +60˚C Humidity : 95% IP : IP65 |
Standard | EN 50556 , TS HD 638 S1, TS EN 12675 ,EN 50293 |
System Standard Features |
Lighting Group : 8 Lighting Group
Pedestrian Cross Button : 4 Button |
Communication |
Ethernet TCP/IP Serial RS 232 |
Optional Feature |
Communication : RS 485 , GSM , GPS SCADA : RUNTIME and Alarm Logger |